Equipower™ – An Electrical fire safety product

Have you stopped and wondered how come a home /office gets burnt completely due to short-circuit, when it already had short-circuit protection installed?

Reason might be that the short-circuit is not necessarily cause of fire or may be the short-circuit was caused due voltage fluctuations.

But wait…  Fluctuations don’t happen in metropolitan cities, do they.  Yes they do.


If you have read this above article in newspaper,  short-circuit protection was already installed yet it caught fire.

The main reason is that sparks/fire caused before short-circuit result in fires. 

Whenever a building/ premise is designed , all safety factors are considered from worst case point of view, except for voltage . Voltage is left to equipments capacity to handle over voltage.

Download Catalogue of Equipower

There are fires caused by incidents like neutral open and double phasing incidents, for which there is no formidable solution. The incident occurs very rarely however when it does it causes huge financial losses due to damages to critical equipments


Equipoweris comprehensive power protection device which acts as an insurance against power fluctuation that could damage your electrical appliances and electronic devices used in your homes and offices .

Equipowerprotects your electrical appliances and electronic devices against high voltage, low voltage, surges, spikes.  However what sets it apart from other protection devices is the ability to protect your equipment in case of neutral open condition. It can easily protect your equipment from voltage as high as 440V in single phase. Equipower increases longevity of equipments and minimizes the risk of damage.


FEATURES Equipower SPD Stabilizer UPS Isolation transformer
Neutral open protection Yes No No No yes
Double phasing protection Yes No No No No
Lightning protection * Yes Yes No No No
Single phasing protection Yes No yes No No
Phase reversal protection. yes No No No No
Over voltage  and under voltage protection yes No yes yes No

Equipower buying process

Find out Capacity of Equipower suitable for your home/ office

Interested to know more about Equipower? Fill up the form below.

// <ins class=”adsbygoogle” style=”display:block; text-align:center;” data-ad-layout=”in-article” data-ad-format=”fluid” data-ad-client=”ca-pub-7118595342999516″ data-ad-slot=”4187689507″></ins> (adsbygoogle = window.adsbygoogle || []).push({});

Video blog#1- neutral open and double phasing protection 


In this video we talk about a possible problem caused by two over head wires touching each other because of trees and causing damage and how contemporary solutions like stabilizers and SPD will not be able mitigate the problem.

If you have faced similar issues and want solution for it please give us your details in form below:

Or you could also visit our online store to range of products we offer.

Click here to visit our online store

The need for double phasing and neutral open protection in Solar power plant design

Solar inv.jpg

Generally any equipment will get damaged due to 3 primary reasons.

  1. Short-circuit
  2. Lightning or surges
  3. Temporary over voltages.

First 2 reasons are taken care of in design and considered as per worst case scenario.

However safeguards for temporary over voltage are generally not taken, certainly not considered as per worst case scenario.

In secondary side of LT transformer , worst case scenario is 440V in single phase.

It happens more often than expected.

Reasons for 440V coming in your supply

  1. Neutral open condition
  2. Double phasing

Causes of neutral open.

  1. Uneven load distribution
  2. Loose wiring.
  3. Accidental breakage
  4. Maintenance work errors

neutral open

Causes of double phasing

  1. Trees falling on overhead wires
  2. Touching of overhead wires running through trees.

double phasing

Majority of projects are located outside of city limits due to roof space constraints and industry requirements. Such scenarios are very common

Not one of the available solar inverter can handle a continuous over voltage of the above nature and will get damaged resulting in down time.

There is strong need of safeguard against such issue in design stage itself so that such issues can be tackled with min losses.

To illustrate, if there is short circuit or lighting strike, the system is designed to handle it. However for continuous over voltage there is not a single solution that can be offered.

There is infact no solution incorporated for 440V in single phase. Most of integrators rely on the inverters capacity of handling voltage fluctuation, and they will definitely get damaged in such a situation.

This is where it is recommended to take cognizance of potential problem that can be taken care in design stage itself.

We specialise in this area i.e. Neutral open and double phasing protection.

You can see our website for details on how we can add value to solar field.

Lightning and surge protection

Surge protection

Surge Protection – a topic that has become increasingly important in recent years as got wide presence across industries. Costly electronic equipment, which is sensitive to voltage peaks on the supply, is no longer found only in offices and factories, but in our homes as well.

Nowadays, highly- sensitive data processing, telecommunication and computer networks form the back-bone of worldwide communications structures without which, no company can survive. Machines and production lines are monitored and controlled by electronic equipments programmed for specific purpose. Even many creative services are no longer conceivable without the aid of computers.
Common to all of them is their dependence on clean electrical energy, within tight tolerance limits and on a continuous supply of power around the clock.

Internal Lightning Protection according to IEC
Lightning current consists of a First stroke followed by a number of subsequent strokes. According to IEC 61024 and IEC 61312, wave shape of the first stroke is calculated to be 10/350 μSeconds.

lightning pulse

Approximately 25 to 30 % of failures in electrical/electronic equipments are because of surges created either by a Lightning or because of switching surges as per the data released by leading insurance companies

power survey

Lightning Peak Current and Frequency of strike:

The maximum value of Lightning current can go up to 200 KA as per IEC 61312 which is in the shape of 10/350 μ Seconds.

Lightning Current Distribution:

According to the standards IEC61024 and IEC 61312, during a lightning strike in a building having an external lightning protection, the lightning current reaches the earth termination. A part of Lightning current goes to earth and remaining part gets coupled into the building through conductive media like Steel reinforcement in Concrete, Earth Conductor Metal Parts connected to earth etc.

lightning distribution

The 100% of lightning energy breaks down as follows according to IEC61312:
–  50% of the lightning current will flow through the ground
–  50% of the lightning current will flow over the connected metal parts of the building (gets coupled into the building)
To protect electrical & electronic equipments inside the building, this 50 % of Lightning current which is entering into the building has to be diverted to the metal parts which is connected from outside. (Metal Water pipe, Metal Sewage pipe, Power lines, data lines etc)

Class B: (Class 1 according to IEC 61643 as well as Class C according to VDE0675)

is an arrester which is designed to carry a lightning current of 10/350 μ Sec duration. Important parameters to be taken care are Lightning Impulse current carrying capacity and Voltage Protection Level (Let through or limiting or clamp voltage)
Class C: (Class II according to IEC 61643 as well as Class C according to VDE0675)

is an arrester which is designed to carry a Surge current in the shape of 8/20 μ Sec. Important parameters to be taken care are Maximum or Nominal Discharge Current carrying capacity and Voltage Protection Level
Class D: (Class III according to IEC 61643 as well as Class D according to VDE0675)

is an arrester which is designed to carry a Surge current in the shape of 8/20 μ Sec as well as tested with a voltage impulse in the shape of 1.2/50 μ Sec. Important parameters to be taken care is Voltage Protection Level

connection diagram SPD

SPD’s are made with Spark Gaps, Metal Oxide Varistors(MOV) Silicon Avalanche Diodes(SAD), Gas Discharge Tubes(GDT) or a combination of these devices
Spark Gaps and GDT’s:

These are called as ‘voltage switching type’ SPD’s. The operating voltage can be determined by the distance between the electrodes. Spark gaps are arresters in which two or more electrodes in series are opposed to each other. The electrodes consist of incombustible material (e.g. carbon or tungsten-copper). Spark gap based arresters used in power line between Line and Neutral should be capable of interrupting the Short Circuit Current (also called as follow current)


Advantages – It can carry Very Large amount of Surge Current for a long Duration
Disadvantage – Need more time to react (about 100 nano sec), high follow Currents

(Metal Oxide Varistors) Varistors are ‘Voltage-dependent resistors’ with a highly non-linear V/I characteristic. Their electrical properties arise from a large number of micro-varistors connected in parallel and in series. The transitions between the micro-varistors can age under the influence of over voltages. Varistors are called as voltage clamping type SPD’s


Advantages – Faster than Spark Gap (approximately 25 nano sec). Limited current carrying Capacity
Disadvantage – Detoriation after every surge. Can create short circuit after a Maximum discharge current flow

Avalanche Diode:

Transzorb diodes (also known as suppressor diodes) are diodes that limit both positive and negative over voltages. Because of their very fast switching performance (in the picosecond’s region) they are well suited for use in precision and data line protection devices. These are also called as voltage clamping type surge arresters

Avalanche diode

Advantages – Very fast response to surges

Disadvantage – Very low surge current carrying capacity

By using Surge arresters at various zone boundaries, Transient over Voltages created due to a Lightning strike or switching surges can be limited below the Voltage Impulse with standing capacities of the equipments in respective zones.

SPD example

Write to us for more queries on queries@microsystemservices.

Also see

1. Does an AVR or surge (spike) suppressor really protect from voltage fluctuations???

2. How  does Servo Stabilizer work?


About the Author (Click on the image to visit his LinkedIn profile


Troubled by equipment breakdowns???

OVCD ad1

GLP- Ground Lift Preventor

The problem of Ground lift.

There was a peculiar incidence with a lift during the work of an almost completed multi-storeyed building. The elevator in the building showed signs of malfunctions. There were incidents of elevator buttons not responding properly, stopping on wrong floors. Users were afraid to use the lifts.

The Engineers of the elevator company were baffled by the problem because all systems seemed to be working fine. There was no damaged part, nor the internal logic was wrong. Then they set about looking at grounding system. But even the grounding systems ( Earth pits) were properly done.

They finally found out the issue. There was welding work going on in the building and workers had actually connected the neutral line to Earthing line . Due to this there was lift in ground potential wrt actual ground. This had caused malfunction in the lifts.

Some time there is situations at many sites where two points have different ground potentials. Generally such issues are to be tackled at design stage by means of Earth pits. However some there are sites where such issues crop up even in case of well designed systems. They can also create an electric shock hazard or may be source of noise or interference. This situation is called Ground Lift.

Two ground points at different potential can produce a Ground loop. It there is connection between these two points via any equipment , current will flow and if the current is high then may be hazardous

Ground lift Preventor

GLP is device which senses leakage voltage between neutral and ground and gives a signal which can be given to relay or contactor to cut off the supply to the system thereby saving it from possible damages.


GLP can be beneficial various areas.

  • Medical equipments
  • Control panels
  • Industrial equipments like CNC machines.
  • Automation equipments like PLC panels
  • Elevators and Escalator

Technical specifications of GLP

System Voltage: 230V AC 50Hz
Supply Voltage range: 180V AC – 250V AC
Supply Current: < 10mA
Auxillary Supply: Not Required
Relay Contact: 5A Potential free. (COM-NO-NC)
Relay Mode:

Relay On at Reset or Power On

Relay Off at Ground Lift

Reset: Auto Reset
Indications: Mains On – Green LED

Grounded – Red LED

Mounting: DIN Rail or Chassis Mounting
Dimensions: 45mm X 76mm X 114mm

400gms. (approx)

Write to us for more queries on queries@microsystemservices.

Also see

1. Does an AVR or surge (spike) suppressor really protect from voltage fluctuations???

2. How does Servo Stabilizer work?


About the Author (Click on the image to visit his LinkedIn profile)

How can OVCD substitute a stabilizer???

In most cases where a comprehensive solution for Power problem is required for any equipment  Let us take an example  of  ATM or any banking requirement.

Generally a combination power protection architecture is a as per below:

Isolation transformer + Servo Stabilizer + Online UPS system Your Appln

All of the above equipments are used to solve different aspects of power problem. Let see them one by one.

Isolation transformer:

  • An isolation transformer is a 1:1 (under load) power transformer used for safety.
  • Without it, exposed live metal in the equipment at a hazardous voltage relative to grounded objects
  • Electrical isolation is considered to be particularly important on medical equipment, and special standards apply. Often the system must additionally be designed so that fault conditions do not interrupt power, but generate a warning.
  • Isolation transformers are also used for the power supply of devices not at ground potential.
  • Designed to block interference caused by ground loops

Servo Stabilizer

  •  Designed to automatically maintain a constant voltage level.

Online UPS system

  • Meant for  emergency power backup  incase of power failure.
  • Provides a stable power Supply.

Seems like a foolproof protection system. However in spite of all this there are issues where equipment get damaged. Servo Stabilizer itself gets damaged. Online UPS gets damaged.  There are issues of Down time and service calls for both.



Double function – a waste

An online UPS is double conversion UPS, meaning that it converts AC –DC (Rectifier charger circuit) and DC to AC (inverter Circuit). So the output of Online UPS is stable irrespective of supply side fluctuations.

It has inbuilt AVR(Automatic Voltage Regulator) system which works as a Stabilizer circuit. It too has operating range like servo Stabilizer 150V-270V. Maximum may be 300V. After this the circuits start malfunctioning. UPS will function properly in this range and will not require a stabilizer.

So essentially Servo stabilizer before an Online UPS is big waste as it does not really protect the Online UPS and UPS will in fact does a better job at stabilizing the voltage levels than a servo Stabilizer.

OVCD – Powerful Alternative

How it works:

  • OVCD is connected at before the equipment in use. Incoming current will first pass through OVCD then into the equipment. OVCD continuously monitors the line voltage.
  • Whenever the voltage is above or below the set voltage limits the OVCD simply cuts the voltage to the equipment thereby saving it from the line disturbance.
  • OVCD will withstand the voltage even as high as 440Volts in single phase . Most equipments get burnt or damaged at this voltage but not OVCD.
  • It however does not stabilize the voltage as in the case of other devices in the same category like Stabilizer, CVTs.
  • When the voltage returns to normal , the OVCD resumes the supply to the equipment automatically with short power-on delay of 3 seconds(configurable). This feature is called the Smart Start. It prevents the initial harmful transient that may damage the Equipment.

How is OVCD better than Stabilizers?

  • Superior protection
  • Occupies less space
  • Lightweight
  • Transformer less design
  • Portable.


Comparison with Stabilizer

Protection up to 440V Yes No
Under voltage / Over voltage protection Yes optional
Protection from spikes Yes No
Lightweight Yes No
Waveform distortion Nil Nil
Response Time Less than 300ms 3 secs
Maintenance Not required Required

Cost comparison.

OVCD is 40% cost effective than any given stabilizer rating.

No price variations on wide range operations. Settings can be custom made.


Why should you consider using OVCD before your equipment?

  • Protection against Extreme over voltage.
  • No problems due to voltage fluctuation.
  • Zero downtime
  • Your equipment becomes more rugged
  • Less service calls = Increased profitability + Increased credibility.
  • Better perception of quality of your system in the minds of the customers
  • Increases the chances of repeat sales or referral sales.


Now you can install your equipment in the worst electrical conditions without being bothered about service calls.


Our proposed solution

Isolation transformer + OVCD + Online UPS system Your Appln

Why trust us on this solution

  • 15 years of experience in this domain.
  • Over 3.5 lakh live installations all across the country and counting
  • Solution is accepted by many UPS manufacturers like Emerson, Delta, Numeric, Techser, Eaton, GE and many more.
  • We have reduced their service issues related to power problems by more than 75%

Write to us for more queries on queries@microsystemservices.