Equipower™ – Home Voltage protector
Have you stopped and wondered how come a home /office gets burnt completely due to short-circuit, when it already had short-circuit protection installed?
Reason might be that the short-circuit is not necessarily cause of fire or may be the short-circuit was caused due voltage fluctuations.
But wait… Fluctuations don’t happen in metropolitan cities, do they. Yes they do.
If you have read this above article in newspaper, short-circuit protection was already installed yet it caught fire.
The main reason is that sparks/fire caused before short-circuit result in fires.
Whenever a building/ premise is designed , all safety factors are considered from worst case point of view, except for voltage . Voltage is left to equipments capacity to handle over voltage.
Download Catalogue of Equipower
There are fires caused by incidents like neutral open and double phasing incidents, for which there is no formidable solution. The incident occurs very rarely however when it does it causes huge financial losses due to damages to critical equipments
Equipower™ is comprehensive power protection device which acts as an insurance against power fluctuation that could damage your electrical appliances and electronic devices used in your homes and offices .
Equipower™ protects your electrical appliances and electronic devices against high voltage, low voltage, surges, spikes. However what sets it apart from other protection devices is the ability to protect your equipment in case of neutral open condition. It can easily protect your equipment from voltage as high as 440V in single phase. Equipower™ increases longevity of equipments and minimizes the risk of damage.
FEATURES | Equipower™ | SPD | Stabilizer | UPS | Isolation transformer |
Neutral open protection | Yes | No | No | No | yes |
Double phasing protection | Yes | No | No | No | No |
Lightning protection * | Yes | Yes | No | No | No |
Single phasing protection | Yes | No | yes | No | No |
Phase reversal protection. | yes | No | No | No | No |
Over voltage and under voltage protection | yes | No | yes | yes | No |
Find out Capacity of Equipower suitable for your home/ office
Interested to know more about Equipower? Fill up the form below.
//pagead2.googlesyndication.com/pagead/js/adsbygoogle.js <ins class=”adsbygoogle” style=”display:block; text-align:center;” data-ad-layout=”in-article” data-ad-format=”fluid” data-ad-client=”ca-pub-7118595342999516″ data-ad-slot=”4187689507″></ins> (adsbygoogle = window.adsbygoogle || []).push({});
Why TATA liebert ( Emerson network power) started using OVCD for protecting its UPS
The year was 1997 , when Tata liebert engineers visited us at an exhibition at world trade centre. They were looking for something that could protect their online UPS in harsh Indian conditions. Their attempts to use stabilizer has not resulted good results. The UPS was high frequency technology relatively new at that time and Tata leibert had ushered it to India from Chinese OEM in hopes to revolutionise the UPS industry with sleek models. The UPS was was more efficient in conversion of power as it had no transformer in it. All of this work was done with help of passive components.
However little did they know that they were in for a nasty surprise. the tolerance of these UPS was about 20% where as voltage fluctuations in India is more than 35%. At times trees would fall on overhead wire causing damage. Weak neutral or disconnection of neutral due to irregularities in distribution was very common. All this contributed to defect ratio of more than 26%. which would mean that 1 out of 4 UPS would come back for repair. This is bad statistic for any product. They were on verge of discontinuing the product line as it seriously dented the image of then no.2 company in online UPS.

This model was designed originally for TATA liebert.
After use of OVCD, their defect ratio went down from 26% to 6% which was a huge improvement. hence they decided to make it standard product for each UPS that would be sold in India.
Many of distributors till date don’t know the exact use of OVCD, except for reason that it is supplied along with UPS and that it was mandatory to install it if they hoped for free servicing under warranty.
OVCD is protection device which safegaurds then equipment against damage caused by extreme overvotlage due to abnormal situations such as
1. neutral open condition
2. double phasing
Why should you consider using OVCD before your equipment?
1.No problems due to voltage fluctuation.
2.Zero downtime
3.Your equipment becomes more rugged
4.Less service calls = Increased profitability + Increased credibility.
5.Better perception of quality of your system in the minds of the customers
6.Increases the chances of repeat sales or referral sales.
USP:
Now you can install your equipment in the worst electrical conditions without being bothered about service calls.
We are looking for appointing dealers across India. If you are interested please drop us a email at info@microystemservices.com
For bulk requirement we offer special rates